In the tables below you will find technical information on the Terlotherm Surface Scraped Heat Exchanger. What capacities can be obtained? What is the heat exchange surface?
| Type |
Product Volume in litres |
Medium Capacity in m3/h |
Drive Capacity in kW/h |
| T0.5-1 |
20 |
5-8 |
2,2 |
| T0-4 |
30 |
5-8 |
3,0 |
| T1-4 |
70 |
10-15 |
5,5-9,2 |
| T1-6 |
70 |
10-15 |
5,5-9,2 |
| T2-4 |
130 |
20-25 |
7,5-11,0 |
| T2-6 |
130 |
20-25 |
7,5-11,0 |
| Type |
|
Number of scrapers |
Heated Surface m2 |
Total height (mm) |
Ground Clearance (mm) |
Product inlet (NW) |
Product outlet (NW) |
| T0.5-1 |
|
8 |
0,6 |
1108 |
556 |
50 |
50 |
| T0-4 |
|
16 |
1 |
1427 |
556 |
80 |
80 |
| T1-4 |
|
24 |
2,4 |
2015 |
675 |
80 |
80 |
| T1-6 |
|
36 |
2,4 |
2015 |
675 |
80 |
80 |
| T2-4 |
|
32 |
4,4 |
2460 |
770 |
80 |
80 |
| T2-6 |
|
48 |
4,4 |
2460 |
770 |
80 |
80 |
| Heating media |
|
Cooling media |
| Steam |
|
Water |
| Water |
|
Chilled Water |
|
|
Brine |
|
|
Glycol |
|
|
Ammonia |